HI6522-02 pH/ORP/ISE and EC/TDS Benchtop Meter Starter Kit
Set yourself up for testing success with our pH/ORP/ISE and EC/TDS Benchtop Meter Starter Kit (HI6522). Our high-performing benchtop meter is ready-to-use straight out of the box and is fully equipped with everything you need to test. Includes necessary modules, electrodes, solutions, and more.
- Precise and consistent. Achieve quick, accurate, and repeatable results
- Reliable and efficient. Ensure quality and meet requirements with easy digital record keeping and increased traceability
- Simple and straightforward. Intuitive navigation menus, built-in help guides, and video tutorials make testing hassle-free
Fits seamlessly into any laboratory or industry environment.
Perfect for chemists, researchers, educators, food manufacturers, beverage producers, and metal finishers to name a few.
HI6522-02 pH/ORP/ISE and EC/TDS Benchtop Meter Starter Kit
HI6522-02 (EU power plug) is supplied with HI6000 housing unit; HI6000-2 pH/ORP/ISE hardware module (installed); HI6000-3 EC hardware module (installed); HI1131B pH electrode; HI7662-TW temperature probe; HI7631233 EC & resistivity probe; pH 4.01 buffer solution, 2 sachets; pH 7.01 buffer solution, 4 sachets; pH 10.01 buffer solution, 2 sachets; electrode cleaning solution, 2 sachets; pH & ORP electrode storage solution (25 mL); 3.5M KCl electrolyte solution (30 mL); capillary pipette, 1 piece; 1413 μS/cm standard solution, 4 sachets; 5000 μS/cm standard solution, 2 sachets; 12880 μS/cm standard solution, 2 sachets; electrode rinse solution, 2 sachets; electrode holder with base plate, screw, cable holder clip (requires mounting); 24 VDC power adapter; USB-C to USB-A cable; meter quick reference guide; hardware modules quick reference guides and quality certificates; probes and meter quality certificate.
| Specification Name | Detail |
|---|---|
| Sku | HI6522-02 |
| pH Range | -2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH |
| pH Resolution | 0.1 pH; 0.01 pH; 0.001 pH |
| pH Accuracy | ±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit) |
| Calibration Points | Up to 5 |
| Calibration Type | Automatic; Semiautomatic; Manual |
| Standard Buffers | Hanna and NIST (pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) |
| Custom Buffers | Up to 5 |
| Custom Group | Option to select from eight standard buffers and user-defined custom buffers |
| First Calibration Point | Offset or Point (user setting) |
| Isopotential Point | -2.000 to 20.000 pH |
| mV Range | -2000.0 to 2000.0 mV |
| mV Resolution | 1 mV; 0.1 mV |
| mV Accuracy | ±0.2 mV ±1 last significant digit |
| mV Calibration | Single point offset, ±2000.0 mV |
| ISE Range | 1.0×10¯5 to 300.0 ppt (g/L or mg/mL) 5.0×10¯3 to 1.0×105 ppm (mg/L or µg/mL) 1.0 to 5.0×107 ppb (µg/L) 1.0×10¯7 to 10.0 M (mol/L) 1.0×10¯4 to 1.0×104 mmol/L 1.0×10¯6 to 60.0 %w/v 5.0×10¯7 to 5.0×107 user |
| ISE Resolution | 1, 2, 3 significant digits |
| ISE Accuracy | ±0.5% (monovalent ions); ±1% (divalent ions) |
| ISE Calibration Points | Up to 5 |
| ISE Calibration Type | All Standards; Standard Group |
| ISE Standards | 7 standard solutions available for each concentration unit |
| ISE Custom Standards | Up to 5 |
| ISE Custom Group | Up to 5 |
| Conductivity Range | 0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm |
| Conductivity Resolution | 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm |
| Conductivity Accuracy | ±1 % of reading or ±0.010 μS/cm, whichever is greater |
| Conductivity Cell Constant | 0.0500 to 200.0000 /cm |
| Conductivity Calibration Type | Automatic; Manual |
| Conductivity Calibration Points | Single; Up to 5 |
| Conductivity Calibration Solutions | 84 μS/cm; 1413 μS/cm; 5000 μS/cm; 12880 μS/cm; 80000 μS/cm; 111800 μS/cm |
| Resistivity Range | 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm |
| Resistivity Resolution | 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm |
| Resistivity Accuracy | ±1 % of reading or ±1 Ω•cm, whichever is greater |
| Total Dissolved Solids (TDS) Range | 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor) |
| Total Dissolved Solids (TDS) Resolution | 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt |
| Total Dissolved Solids (TDS) Accuracy | ±1 % of reading or ±0.01 ppm, whichever is greater |
| Salinity Range | 0.00 to 42.00 PSU (Practical Salinity Scale); 0.00 to 80.00 ppt (Natural Sea Water); 0.0 to 400.0 % (Percent Scale) |
| Salinity Resolution | 0.01 PSU; 0.01 ppt; 0.1 % |
| Salinity Accuracy | ±1 % of reading |
| Salinity Calibration | 1 point, using 100 % salinity calibration solution (% scale only) |
| Temperature Range | −20.0 to 120.0 °C; −4.0 to 248.0 °F; 253.2 to 393.2 K |
| Temperature Resolution | 0.1 °C; 0.1 °F; 0.1 K |
| Temperature Accuracy | ±0.2 °C; ±0.4 °F; ±0.2 K |
| Temperature Calibration | Single point, adjustable |
| Temperature Compensation | For pH: Automatic; Manual For Conductivity: Linear; Natural; Standard; Disabled |
| Reference Temperature | For Conductivity: 5.0 to 30.0 °C (41.0 to 86.0 °F , 278.2 to 303.2 K) |
| Temperature Coefficient | For Conductivity: 0.00 to 10.00 %/°C |
| Reading Mode | Direct Direct/Autohold ISE Only: Known Addition, Known Subtraction, Analyte Addition, Analyte Subtraction Conductivity Only: Direct/USP |
| Basic View | Measurement data; Measurement profile (if enabled); Stability status |
| Simple GLP View | Basic view information For pH: pH Last calibration date, slope, offset (pH, Rel. MV – ISE Only) For Conductivity: Last calibration date and offset |
| Full GLP View | Simple GLP Information; Calibration point details (pH, ISE, Conductivity, and Salinity) |
| Graph View | Basic view information; measurement versus time graph |
| Table View | Basic view information; Table with measurements updated every second |
| Reading Stability Criteria | Accurate; Medium; Fast |
| Reading Sampling Rate | 1000 ms |
| Logging Type | Automatic; Manual; Autohold |
| Logging Number of Records | 50,000 maximum per file and stores at least 1,000,000 data points per user |
| Logging Automatic Interval | 1, 2, 5, 10, 30 seconds and 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes |
| Logging Sample ID | Incremental Mode; Manual |
| Logging Export Option | .CSV file format |
| Connectivity USB-A | 2 ports keyboard and/or printer input USB Flash Drive |
| Connectivity USB-C | 1 port PC Connectivity and USB-C Type Flash Drive |
| Connectivity Wi-Fi & Ethernet | FTP; Web Server (Log transfer and download); Email |
| Connectivity RS232 | Connecting peripherals |
| Calibration Reminder | Daily (0 minutes to 23 hours and 59 minutes); Periodic (1 minute to 30 Days, 23 hours and 59 minutes); or Disabled |
| Users | Up to 9 users and the default administrator account |
| Power Supply | DC adapter 100-240 VAC to 24 VDC 2A |
| Environment | 0 to 50 °C / 32 to 122 °F / 273 to 323 K maximum 95 % RH non-condensing |
| Dimensions | 205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “) |
| Weight | 8.05 lbs |