HI8720 Dual Setpoint - ORP analog Controller with 4 to 20mA

Product Code : HI8720

Category : Plating

Catalog : sorry not ready

Product information "HI8720 Dual Setpoint - ORP analog Controller with 4 to 20mA"

Inputs: BNC connector, Direct wire connection with amplified probe (supports HI 1006 series probes) and 4-20 mA from a transmitter

Selectable manual ON, OFF and automatic dosing control for alkaline, acid and REDOX dosing with indicator
Auto-diagnostic test for instrument status troubleshooting
Operational mode LED indicators
Supports potential matching pin connection
Both 4-20 and 0-20 mA output
±5V outputs for amplified electrodes
Backlit LCD
Transparent splash-proof cover



This instrument allows the selection of a set point for oxidizing or reducing dosage.

When used in conjunction with the HI 8710 pH controller, the ODCD (ORP dosing consent device) function (featured by the HI 8710) will ensure that the ORP dosage will start only when the pH level
is correct.

These instruments have been designed for easy and fast installation and are provided with membrane keypads on the front panel, large display, and autodiagnostic functions.

Each model accepts either a direct input from an ORP electrode or from a transmitter through 4-20 mA input. The instrument also provides ±5V power output and input terminals for amplified electrodes.

Moreover, you can choose the output configuration for connecting a recorder or a PLC, between 0-20 or 4-20 mA.



Order Information:
The HI 8720 is supplied complete with mounting brackets and instructions.


Specification :
Range ±1999 mV
Resolution 1 mV
Accuracy
@ 20 °C ±5 mV; ±0.5% (input from transmitter)
Input high impedance 1012 Ohm; reference and matching pin inputs are available; 4-20 mA
Power Output ±5 Vcc; 150 mA max load for amplified electrodes
Calibration offset: ±200 mV with CAL trimmer
Recorder Output 0-20 mA or 4-20 mA (isolated)
Setpoint Relay 1, isolated, 2 A, max 240 V, resistive load, 1000000 strokes (not fuse protected)
Setpoint Range ±1999 mV
Alarm Relay 1, isolated, 2 A, max 240 V, resistive load, 1000000 strokes (not fuse protected)
Alarm Range 10 to 300 mV
Dosing Control OFF/AUTO/ON with selection switch
Over Dosing Control adjustable, from 5 min to 60 min with knob or disable by wire strap - on rear panel
Backlight continuous on
Power Supply 115 VAC ±10% or 230 VAC ±10%; 50/60 Hz
Enclosure flame retardant ABS body and front panel; transparent splash-proof front cover
Environment -10 to 50°C (14 to 122°F); RH max 95% non-condensing
Panel Cutout 141 x 69 mm (5.6 x 2.7’’)
Weight 1 kg (2.2 lb.)