HI2030 edge™ - Conductivity (EC / TDS / Salinity / °C) Meter

Product Code : HI2030

Category : Industrial

Catalog : sorry not ready

Product information "HI2030 edge™ - Conductivity (EC / TDS / Salinity / °C) Meter"

Hanna Instruments is proud to introduce the world’s most innovative pH, EC, and DO meter... edge™.


edge is thin and lightweight, measuring just 1?2” thick and weighing less than 9 ounces. edge has an incredibly wide viewing angle, 5.5” LCD and a sensitive capacitive touch keypad.


edge measures pH, conductivity and dissolved oxygen through its unique digital electrodes. These digital electrodes are auto-recognized. Providing sensor type, calibration data and serial number when connected to edge with an easy to plug-in 3.5mm connector. edge’s versatile design is equally at home in your hand, on a lab bench or mounted on a wall. It simplifies measurement, configuration, calibration, diagnostics, logging and transferring data to a computer or a USB drive.
edge features Hanna’s exclusive CAL-CHECK® to warn you if the pH electrode you are using is not clean or if your buffers are contaminated during calibration. Indicators are also displayed for response time and probe condition that is based on the offset and slope of the electrode. We have also added to SENSOR-CHECK for sensors with matching pin: now it warns you if the pH bulb is cracked or if the junction of the electrode is clogged.


edge is the culmination of Hanna’s vision, design capabilities, integrated production facilities, and world class R&D teams. With edge, Hanna has set the new standard!

FEATURES:

Thin, Lightweight Design
Multiparameter (ability to measure pH, EC or DO)
pH Electrode Monitoring Technology (Sensor Check and Cal Check)
Multiple Calibration Points
Built-in Temperature Sensor on all Electrodes
Log on Demand
Large, easy to read LCD
Capacitive Touch
Dual USB ports
GLP feature
Rechargeable Battery



Order Information: edge HI2030-02 (230V)includes benchtop docking station with electrode holder, wall mount cradle, USB cable, 763100 Conductivity probe, 3 sachets of 1413 µS/cm conductivity standard, 3 sachets of 12880 µS/cm conductivity standard, 5 VDC power adapter, and instruction manual.

Specification :
EC Range 0.00 to 29.99 µS/cm 30.0 to 299.9 µS/cm 300 to 2999 µS/cm 3.00 to 29.99 mS/cm 30.0 to 200.0 mS/cm up to 500.0 mS (absolute EC)*
TDS Range 0.00 to 14.99 mg/L (ppm) 15.0 to 149.9 mg/L (ppm) 150 to 1499 mg/L (ppm) 1.50 to 14.99 g/L 15.0 to 100.0 g/L up to 400.0 g/L (absolute TDS) with 0.8 TDS factor*
Salinity Range 0.0 to 400.0% NaCl – Percent Scale 0.00 to 42.00 PSU – Practical Salinity Scale 0.0 to 80.0 g/L – Natural Seawater Scale
EC Resolution 0.01 µS/cm, 0.1 µS/cm, 1 µS/cm, 0.01 mS/cm, 0.1 mS/cm
TDS Resolution 0.01 mg/L (ppm), 0.1 mg/L (ppm), 1 mg/L (ppm), 0.01 g/L, 0.1 g/L (0.8 TDS factor)
Salinity Resolution 0.1% NaCl – Percent Scale 0.01 PSU – Practical Salinity Scale 0.01 g/L – Natural Seawater Scale
EC Accuracy @ 25°C/77°F ±1% of reading (+/-0.5 µS/cm or 1 digit, whichever greater)
TDS Accuracy @ 25°C/77°F ±1% of reading (+/-0.03 ppm or 1 digit, whichever greater)
Salinity Accuracy @ 25°C/77°F ±1% of reading for all scales
EC Calibration Points EC 1 point cell factor calibration 1 point offset calibration with probe in air (0.00 µS/cm) TDS Through EC calibration NaCl 1 point
EC Temperature Compensation No TC or ATC: -20.0 to 120.0°C; -4.0 to 248.0°F
EC Temperature Coefficient 0.00 to 6%/°C (for EC and TDS only) default value is 1.9%/°C
Electrode Condition YES– Standard mode (pH only)
Electrode Response YES– Standard mode (pH only)
Out of Calibration Range YES– Standard mode (pH only)
EC and NaCl Standards EC 84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm NaCl HI 7037 100% NaCl seawater standard
TDS Factor 0.40 to 0.80 (default value is 0.50)
Temperature Range [°C/°F] -20.0 to 120.0°C; -4.0 to 248.0°F
Temperature Accuracy @ 25°C/77°F ±0.5°C; ±1.0°F
°C/°F YES
GLP YES
Keyboard 9 Keys (on/off, 8 dedicated)
Log Feature Up to 1000 records organized in Manual Log on demand (Max. 200 logs), Manual log on Stability (Max. 200 logs), Interval logging with up to 100 lots (Max. 600 logs/lot )
Storage Interface USB
PC Interface Micro USB
Power Supply 5 VDC
Dimensions 202 x 140 x 12.7 mm (8” x 5.5” x .05”)
Weight 250 grams (8.82 oz.)
* with temperature compensation function disabled
** temperature limits will be reduced to actual probe/sensor limits
*** pH 3.00 is only visible when using specific pH electrodes and will replace pH 4.01 buffer