HI2002 edge™ - pH/ORP meter with CAL Check

Product Code : HI2002

Category : Food

Catalog : sorry not ready

Product information "HI2002 edge™ - pH/ORP meter with CAL Check"

?????Digital pH Electrodes

edge pH electrodes are highly advanced, featuring a built-in microchip that stores calibration information that is automatically retrieved by edge once the electrode is plugged in. With a digital electrode it is possible to change electrodes without having to recalibrate since the calibration information is stored in the pH electrode and not the meter. This allows flexibility for the user that measures pH with more than one electrode.

CAL Check

Hanna’s exclusive CAL Check feature analyses the pH electrode response in the pH buffers during the calibration process to alert the user of potential problems such as contaminated buffer and clean electrode. After calibration, indicators for probe condition and response time are displayed on the measurement screen. The probe condition indicator is based on offset and slope characteristics of the pH electrode.
Wall Mount

Using the wall mount cradle (included), edge can be placed on a wall, leaving zero footprint on the benchtop space. The cradle has a built-in connector to power edge and charge its batteries. edge's zero footprint is designed to save you valuable benchtop space.
Cradle and Electrode Holder

edge is equipped with a benchtop cradle with an adjustable swivel electrode holder to charge and hold the edge securely in place at the optimum viewing angle.
Two USB Ports

edge includes one standard USB for exporting data with a flash drive and a second micro USB port for you to connect to a computer for file export and for charging your edge when the cradle is not available.
Data Logging

edge allows you to store up to 1000 log records of data. Data sets include readings, GLP data, date and time.
pH Specifications
pH Range -2.000 to 16.000 pH (Standard Mode), -2.00 to 16.00 pH (Basic Mode)
pH Resolution 0.001 pH, 0.01 pH
pH Accuracy (@25ºC/77ºF) ±0.01 pH, ±0.002 pH
pH Calibration 5 points (Standard mode)? 1.68, 4.01 (3.00†), 6.86, 7.01, 9.18, 10.01, 12.45, and two custom buffers; 3 points (Basic mode) 4.01; 6.86; 7.01; 9.18; 10.01
pH Temperature Compensation ATC: -5.0 to 100.0ºC; 23.0 to 212.0°F*
mV Range ±1000.0 mV; ±2000.0 mV
mV Resolution 0.1 mV
mV Accuracy ±0.2 mV (±999.9 mV); ±1 mV (±2000 mV)
Relative mV Calibration Single point calibration








Temperature Specifications
Temperature Range -20.0 to 120.0 ºC, -4.0 to 248.0 °F
Temperature Resolution 0.1 °C, 0.1 °F
Temperature Accuracy ±0.5 °C, ±0.9 °F
°C/°F Yes




Additional Specifications
pH Electrode Diagnostics Glass and reference junction diagnostics ( HI 11311 & HI 12301 only), out of calibration range , probe condition, response time
GLP Yes
Logging up to 1000*** records organized in: Manual log-on-demand (Max. 200 logs), Manual log-on-stability (Max. 200 logs), Interval logging *** (Max. 600 samples; 100 lots)
Connectivity 1 micro USB port for charging and PC connectivity, 1 USB port for storage
Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing
Battery Type/Life Built-in rechargeable battery with up to 8 hours of continuous use
Power Supply 5 VDC adapter (included)
Dimensions 202 x 140 x 12.7mm (8” x 5.5” x 0.5”)
Weight 250 g (8.82 oz)
Ordering Information edge® HI2002 includes benchtop docking station with electrode holder, wall mount cradle, USB cable, HI11310 glass body refillable pH electrode with temperature sensor, 2 sachets each of pH 4, 7, 10, cleaning solution, 5 VDC power adapter and instruction manual.
Notes

* temperature limits will be reduced to actual probe/sensor limits
*** For standard mode only (logging)
† pH 3.00 is only visible when using specific pH electrodes and will replace pH 4.01 buffer