HI122 pH / ORP / °C Meter / 5-Point Calibration with Built-in Printer

Product Code : HI122

Category : pH (Meters)

Catalog : sorry not ready

Product information "HI122 pH / ORP / °C Meter / 5-Point Calibration with Built-in Printer"

pH Calibration Check™

Electrode response time
Five pH calibration points
Seven standard and two custom buffers
Out of calibration range warning
Large, custom LCD
Built-in impact printer
Automatic data logging of 2000 records and log on demand
GLP capabilities
High and low audible alarms



HI 122 is a benchtop instrument featuring a built-in printer, Calibration Check™, electrode response time and condition monitoring, and enhanced diagnostic messages during calibration.

This meter uses HANNA’s “P” series of electrodes. For more accuracy, these meters also check if the measurement is outside the calibration range and warns the user in case measurements are too far outside the calibration points. Calibration can be performed in up to five points using the standard seven buffers that are automatically recognized, or by using two custom buffer values. The buffer(s) used during calibration are displayed on the LCD even when in measurement mode.

Users can log on demand up to 50 samples (50 samples per channel for dual channel model). These meters have automatic data logging of up to 1000 points (1000 points per channel for dual channel model) with flexible starting and stopping criteria.

This instrument provides GLP capabilities that allows for the storage and retrieval of all data regarding pH, rel mV, EC and NaCl calibration as well as data regarding the maintenance and status of the electrode.

Printing

The built-in impact printer incorporated into the HI 122 uses regular paper that does not fade with time. A complete set of information based on the measured, set or recorded data can be printed on demand (for current reading in measurement mode, GLP and SETUP modes) or automatically (for autolog and log on demand modes). These models also allow users to print detailed information in four languages for specific help screens and instrument set-up.



Order Information:
HI 122-02 (230V) is supplied with HI 1131P pH electrode, HI 7662-T temperature probe, HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer solution sachet, HI 7071S electrolyte solution (30 mL), (5) paper rolls, 12 VDC adapter and instructions.


Specifications :
Range pH -2.00 to 16.00 pH; -2.000 to 16.000 pH
ORP ±999.9 mV; ±2000 mV
Temperature -20.0 to 120.0ºC (-4.0 to 248.0ºF)
Resolution pH 0.01 pH / 0.001 pH
ORP 0.1 mV / 1 mV
Temperature 0.1°C (0.1ºF)
Accuracy pH ±0.01 pH / ±0.002 pH
ORP ±0.2 mV (±699.9 mV) / ±0.5 mV (±999.9 mV) / ±1 mV (±2000 mV)
Temperature ±0.4°C (±0.7ºF) excluding probe error
BNC Inputs 1 for pH electrode
Calibration Check Status of electrode condition and response time
status of the buffer solutions during calibration
Relative mV
Offset Range ±2000 mV
pH Calibration automatic, up to 5 points with 7 memorized values (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 2 custom buffers
Temperature Compensation Automatic or manual, -20.0 to 120°C (-4 to 248°F)
pH Electrode HI 1131P, glass body, refillable, BNC + pin connectors, 1 m cable (included)
Temperature Probe HI 7662-T with 1 m (3.3') cable (included)
Input Impedance 1012 Ohm
Log-On-Demand 50 samples
Automatic Logging 1000 samples
PC Connection RS232 serial port, opto-isolated
Printer built-in dot matrix printer, with 44 mm plain paper
Power Supply 12 Vdc adapter (included)
Environment 0 to 50°C (32 to 122°F); RH max 95%
Dimensions 280 x 203 x 84 mm (11.0 x 8.0 x 3.3")
Weight 1.9 kg (4.2 lbs.)