HI98594 Portable Multiparameter pH/EC/Turbidity/opdo® Meter with Bluetooth®
Product Code : HI98594
Category : Hanna best sellers
Catalog : hi98594_portable_multiparameter_ph_ec_turbidity_opdo®_meter_with_bluetooth®_support.pdf
Our Portable Multiparameter pH/EC/Turbidity/odpo® Meter with Bluetooth® (HI98594) makes testing simple and convenient. Monitor up to 14 different water quality parameters with just one device including pH, ORP, turbidity, EC/TDS, dissolved oxygen, resistivity, salinity, seawater σ, atmospheric pressure, and temperature.
Be up in running in no time with this complete kit! This meter arrives in a protective, heavy-duty carrying case and is ready to use right from the get-go with all essential supplies and accessories stored in one place. Customize this meter to fit your testing requirements and choose from several cable length options.
- Handheld, portable size. Test anywhere in the field or at multiple facility checkpoints with this versatile meter. Easily take this meter with you and measure wherever you need to
- Rugged and durable. This tough meter is waterproof and built to withstand harsh outdoor environments and conditions. Can handle the knocks and drops that may occur while testing
- Fast and accurate. Our high-performance meter delivers precise results in the palm of your hand. Cut down on testing time and collect quick, consistent, and reliable measurements on the spot
| Specification Name | Detail |
|---|---|
| sku | HI98594 |
| pH Range | 0.00 to 13.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.05 pH (Accuracy is evaluated with a calibrated system at ambient temperature.) |
| pH Calibration | One point using HI9828-20 Quick Calibration Solution Up to three points using pH 4.01, pH 6.86, pH 7.01, pH 9.18, pH 10.01 standard buffers and one customer buffer |
| mV Range | ±600.0 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±3.0 mV (Accuracy is evaluated with a calibrated system at ambient temperature.) |
| ORP Range | ±2000.0 mV |
| ORP Resolution | 0.1 mV |
| ORP Accuracy | ±10.0 mV (Accuracy is evaluated with a calibrated system at ambient temperature.) |
| ORP Calibration | Automatic at one custom point (relative mV) |
| Temperature Range | -5.00 to 50.00 °C; 23.00 to 122.00 °F; 268.15 to 323.15 K |
| Temperature Resolution | 0.01 °C; 0.01 °F; 0.01 K |
| Temperature Accuracy | ±0.15 °C; ±0.27 °F; ±0.15 K |
| Temperature Calibration | Automatic at one custom point |
| EC Range | 0 to 200 mS/cm; 0 to 400 mS/cm (absolute) |
| EC Resolution | Manual: 1 µS/cm 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm; 1 mS/cm Automatic: 1 µS/cm from 0 to 9999 µS/cm 0.01 mS/cm from 10.00 to 99.99 mS/cm 0.1 mS/cm from 100.0 to 400.0 mS/cm Automatic (mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm 0.01 mS/cm from 10.00 to 99.99 mS/cm 0.1 mS/cm from 100.0 to 400.0 mS/cm |
| EC Accuracy | ±1% of reading or ±1 µS/cm, whichever is greater (Accuracy is evaluated with a calibrated system at ambient temperature.) |
| EC Calibration | One point using HI9828-20 Quick Calibration Solution One point using 84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm standard solutions or custom point |
| TDS Range | 0 to 400000 ppm (mg/L) (the maximum value depends on the TDS factor) |
| TDS Resolution | Manual: 1 ppm (mg/L) 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L) Automatic: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L) 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L) 0.1 ppt (g/L) from 100.00 to 400.0 ppt (g/L) Automatic ppt (g/L): 0.001 ppt (g/L) from 0.000 to 9.999 ppt (g/L) 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L) 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L) |
| TDS Accuracy | ± 1 % of reading or ± 1 ppm (mg/L), whichever is greater |
| TDS Calibration | Based on conductivity or salinity calibration |
| DO Range | 0.0 to 500.0 % saturation; 0.00 to 50.00 ppm (mg/L) |
| DO Resolution | 0.1 % saturation; 0.01 ppm (mg/L) |
| DO Accuracy | ±1.5 % of reading from 0.0 to 200.0 % saturation ±5 % of reading from 200.0 to 500.0 % saturation ±1.5 % of reading from 0.00 to 20.00 mg/L ±5 % of reading from 20.00 to 50.00 mg/L (Accuracy is evaluated with a calibrated system at ambient temperature.) |
| DO Calibration | One point, quick calibration in water-saturated air One or two points, at 100 % and 0 % One point, using a custom solution (% saturation or mg/L) |
| Barometric Pressure Range | 450.0 to 850.0 mmHg; 17.72 to 33.46 inHg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa |
| Barometric Pressure Resolution | 0.1 mmHg; 0.01 inHg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
| Barometric Pressure Accuracy | ±3.0 mmHg within ±15 °C from calibration temperature |
| Barometric Pressure Calibration | Automatic at one custom point |
| Resistivity Range | 0 to 999999 Ω·cm; 0 to 1000.0 kΩ·cm (depending on resistivity reading); 0 to 1.000 MΩ·cm |
| Resistivity Resolution | 1 Ω·cm; 0.1 kΩ·cm; 0.0001 MΩ·cm |
| Resistivity Calibration | Based on conductivity calibration |
| Salinity Range | 0.00 to 70.00 PSU |
| Salinity Resolution | 0.01 PSU |
| Salinity Accuracy | ±2 % of reading or ±0.01 PSU, whichever is greater |
| Salinity Calibration | One point, using a custom solution |
| Seawater Sigma Range | 0.0 to 50.0 σt, σ0,σ15 |
| Seawater Sigma Resolution | 0.1 σt, σ0,σ15 |
| Seawater Sigma Accuracy | ±1.0 σt, σ0,σ15 |
| Seawater Calibration | Based on conductivity or salinity calibration |
| Turbidity Range | 0.0 to 99.9 FNU; 100 to 1000 FNU |
| Turbidity Resolution | 0.1 FNU from 0.0 to 99.9 FNU; 1 FNU from 100 to 1000 FNU |
| Turbidity Accuracy | ±0.3 FNU or ±2 % of reading, whichever is greater (Accuracy is evaluated with a calibrated system at ambient temperature.) |
| Turbidity Calibration | Automatic Up to three points using 0 FNU, 20 FNU, 200 FNU, or custom |
| DO Pressure Compensation | Automatic; 450 to 850 mmHg |
| Temperature Compensation | Automatic; -5 to 50 °C; 23 to 122 °F; 268.15 to 323.15 K |
| Logging Memory | Interval logging 50000 records Log-on-demand (all parameters) 20000 records |
| Logging Interval | 1 second to 3 hours |
| USBC (Host) Functions | Mass-storage host |
| USBC (Device) Functions | Mass-storage device |
| Protection Rating | IP67 |
| Environment | 0 to 50 °C (32 to 122 °F); RH 100 % |
| Battery Type | 4 x 1.5V AA alkaline batteries 1 X internal, Li-ion rechargeable battery |
| Battery Life | ≈ 126 hours 90 hours using alkaline AA batteries 36 hours using Li-ion battery (Estimated time given without backlight and Bluetooth®.) |
| Dimensions | 185 X 93 X 35.2 mm (7.3 X 3.6 X 1.4") |
| Weight | 435 g (13.3 oz) (with batteries) |